We've launched our new site at www.openlighting.org. This wiki will remain and be updated with more technical information.
Running the tests
From wiki.openlighting.org
This describes how to run the RDM Responder Tests. Before starting you may want to read the Responder Testing FAQ.
Contents
Install OLA
Follow one of OLA on OS X or OLA on Linux or OLA on Windows with VMWare to install OLA. If you want the biggest benefit from the tests you should use the version in the git repo as tests are added regularly.
Setup the Test Rig
The following controller devices are supported:
DMXter Instructions
You need to put the DMXter into dongle mode. From the RDM menu, hold the left and right buttons and then hit the center button. The display should change to "USB Dongle Mode".
RDM TRI Instructions
In order to use the full test suite you need to use this interface in raw RDM mode. This allows the test suite to send malformed & unusual RDM packets to check the responder does the right thing. [TODO(someone): confirm which version of the firmware you need for this]
To enable raw rdm mode, in ~/.ola/ola-usbpro.conf, change the tri_use_raw_rdm line:
tri_use_raw_rdm = true
Discovering Responders
Connect the device under test to the controller device and start olad. Patch the output port on the controller device to a universe (UNIVERSE_NUMBER). Then run ola_rdm_discover, you should see the responder's UID appear:
$ ola_rdm_discover -u UNIVERSE_NUMBER 00a1:00010003 7a70:ffffff00
Running the Tests
Warning: The tests send SET messages to the broadcast UIDs. This means that they will change the start address, device label etc. of all devices connected to the controller. Think twice about running this on your production lighting rig.
The tests are written in Python and run using ola_rdm_test.py. Below is the output from a typical test run:
$ ./ola_rdm_test.py --universe 1 00a1:00010003 Starting tests, universe 3, UID 00a1:00010003 SetManufacturerLabel: Passed SetSoftwareVersionLabel: Passed GetManufacturerLabel: Passed GetSoftwareVersionLabelWithData: Failed ... ------------- Warnings -------------- ------------ By Category ------------ Product Information: 7 / 7 100% RDM Information: 1 / 1 100% Core Functionality: 2 / 2 100% Error Conditions: 10 / 16 62% DMX512 Setup: 3 / 3 100% ------------------------------------- 29 / 30 tests run, 23 passed, 6 failed, 0 broken
Useful Options
ola_rdm_test.py has some options which can assist in debugging failures. For a full list of options run with -h
- -d, --debug
- Show all debugging output, including actual & expected responses.
- -l, --log
- Log the output of the tests to a file. The UID and timestamp is appended to the filename
- -t Test1,Test2 , --tests=Test1,Test2
- Only run a subset of the Tests. Only the tests listed (and their dependencies) will be run.