The Open Lighting Project has moved!
We've launched our new site at www.openlighting.org. This wiki will remain and be updated with more technical information.
We've launched our new site at www.openlighting.org. This wiki will remain and be updated with more technical information.
Difference between revisions of "RDM Test Output"
From wiki.openlighting.org
(Created page with "The RDM Responder Tests can produce quite a bit of output. This guide covers how to interpret the output and diagnose failures. First a quick overview…") |
(No difference)
|
Revision as of 09:11, 9 November 2012
The RDM Responder Tests can produce quite a bit of output. This guide covers how to interpret the output and diagnose failures.
First a quick overview of how the tests are structured:
Test Categories
Tests are grouped according to the sections in the RDM Categories/Parameter ID Defines table in the E1.20 document. There are some extra categories for specific behavior like error conditions and sub device handling.
Test States
There are four possible result states for a test:
- Passed
- The responder replied with the expected result
- Failed
- The responder failed to reply, or replied with an un-expected result
- Not Run
- This test wasn't run because the responder doesn't support the required functionality or a previous test failed.
- Broken
- An internal error occurred, this indicates a programming error or an error with the test rig.
Log Messages
- Warnings
- Warnings indicate behavior that doesn't match the standard, but is unlikely to cause usability issues. Warnings are printed in the summary section of the test output.
- Advisory Messages
- Advisory messages indicate issues that are not covered by the standard but are likely to cause problems i.e a sensor temperature out side of the stated scale range.