Personal tools
The Open Lighting Project has moved!

We've launched our new site at www.openlighting.org. This wiki will remain and be updated with more technical information.

Difference between revisions of "Talk:DMX512-A"

From wiki.openlighting.org

Jump to: navigation, search
m (Talk:DMX moved to Talk:DMX512-A)
(clean-up)
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
== Timings ==
 
The clock rate is 250 kHz so each symbol bit on the wire is 4 microseconds long (period time).
 
  
Frame rate is ??
+
== connectors ==
Packet rate is typically around 44 Hz when all frames are sent.
+
The use of modular plugs like 8-position modular connector (8P8C or RJ45) or 6P4C (RJ11)? Is there any allowance for other than 8 position modular connectors?
 +
Some product (cheap dimmers) have 6 position connectors (RJ11).
  
== RDM protocol additions ==
+
== Sender/receiver topologies ==
The name of the standard is: ANSI/ESTA 1.20, Entertainment Technology - Remote Device Management over USITT DMX512
 
???
 
Mark (beginning of frames)
 
Mark After Break (beginning of frames)
 
 
 
Mark time between packet
 
Mark time between frames
 
 
 
DMX Timing table
 
 
 
Symbol length is 4 +/- 0.08us for 245 - 255 k baud/s, with non-return-zero between symbol bits. To transmit 8 data bits it take 11 symbols because the use of one start bit and two stop bits around each data byte.
 
 
 
{|border=1
 
||'''Name''' || '''Tx requirement''' || '''Typical/suggested Tx''' || '''Rx requirement'''
 
|-
 
||Break <br> (the packet start) || >= 92 us || 100-120 us (Ujjal) <br> 176 us (DMX512-A-2004)|| >= 88 us
 
|-
 
||Mark after break <br> (in packet start) || >= 8 us || 12 us (Ujjal) || 4 us - < 1 s backward compatible <br>8 us - < 1 s DMX512-A-2004
 
|-
 
||Slot/frame width || 44 us || 44 us || 44 us
 
|-
 
||Inter-slot/frame time || < 1 s || minimal || < 1 s ?
 
|-
 
||Mark before break <br> (Idle time after packet)|| < 1 s || 0 - 1 s  ? || < 1 s ?
 
|-
 
||Break to Break time, also<br>(DMX2512 packet length) || 1204 us -1 s || || 1196 us - 1.25 s
 
|}
 
 
 
Idle must be high level
 
Note that "Mark after break" was changed from 4 to 8 us minimum length in 1990, and receivers can be backward compatible.
 
The slot time must be precise, or else the receiver should discard the whole packet, e.g. if the second stop bit is missing.
 
 
 
There must be at least one packet with start code=0 per second, and a receiving product must specify what happens when this time is exceeded.
 
 
 
Ervin Rol has shown the timing values from the DMX standard.
 
 
 
 
 
== Use of category 5 UTP or STP ==
 
New cable types is used, and may be officially accepted.
 
http://www.usitt.org/standards/DMX512_FAQ.html#FAQ_08
 
 
 
The use of modular plugs like 8P8C (RJ45) or 6P4C (RJ11)
 
 
 
The cabling for DMX512-A should be described in the document  called "BSR E1.27-1 -- Portable Control Cables for Use with USITT DMX512/1990 and E1.11 [DMX512-A]"
 
 
 
== Sender/receiver topologiess ==
 
 
To avoid ground loops and improve reception performance, transmitters and/or receivers can be grounded/floating/non-isolated ???
 
To avoid ground loops and improve reception performance, transmitters and/or receivers can be grounded/floating/non-isolated ???
 
http://www.usitt.org/standards/DMX512_FAQ.html#FAQ_15
 
http://www.usitt.org/standards/DMX512_FAQ.html#FAQ_15
Line 59: Line 12:
 
Receivers should be ...?
 
Receivers should be ...?
  
== More suggestions and info ==
 
 
Here is also a nice overview of the different parts of a DMX packet with timings etc.:
 
http://www.erwinrol.com/index.php?stagecraft/dmx.php
 
  
 
== Voltages ==
 
== Voltages ==
 
The power dissipation in the 120 Ohm terminating resistors depends on the differential voltage between the two data wires.
 
If the transmitter only makes a 5 V differential voltage, the power dissipation is P= U*U/R= 5*5/120 = 208 mW.
 
 
According to http://focus.ti.com/lit/an/slla070c/slla070c.pdf the maximum absolute differential voltage allowed by the EIA485 standard is 6 V.
 
This give the maximum power dissipation is P= U*U/R= 6*6/120 = 300 mW. So it is best to use 1/2 W resistors.
 
  
 
At http://www.dmx512-online.com/physl.html there is an example wit D1+ at +5V and D1- at -5V, and considering [http://focus.ti.com/lit/an/slla070c/slla070c.pdf page 12 in this document from TI] it is presumably a wrong interpretation.
 
At http://www.dmx512-online.com/physl.html there is an example wit D1+ at +5V and D1- at -5V, and considering [http://focus.ti.com/lit/an/slla070c/slla070c.pdf page 12 in this document from TI] it is presumably a wrong interpretation.
Line 76: Line 19:
 
[http://www.dmx512-online.com/physl.html This web page] cites RS485 as having a upper limit of +12/-7 V with respect to ground. This probably refers to common mode loading voltages that receivers must work with. I.e. one of the data wires is allowed to reach +12 or -7 V but the opposite wire must not be at the other extreme, but only differ by 6 V maximum.
 
[http://www.dmx512-online.com/physl.html This web page] cites RS485 as having a upper limit of +12/-7 V with respect to ground. This probably refers to common mode loading voltages that receivers must work with. I.e. one of the data wires is allowed to reach +12 or -7 V but the opposite wire must not be at the other extreme, but only differ by 6 V maximum.
  
Transciever chips made for 5 V:
 
Linear Technology LTC485: http://www.linear.com/pc/productDetail.jsp?navId=H0,C1,C1007,C1017,P2064
 
National semiconductor LMS485: http://www.national.com/mpf/LM/LMS485.html
 
National semiconductor DS75176B (used in Martin PAL 1200, Lite-Puter DX-625 and a cheap Eurolite DMX console) http://www.national.com/mpf/DS/DS75176B.html
 
  
  
a but the spec says that the differential maximum from transmitters is 6 V, according to
+
 
  
 
== Debugging tips ==
 
== Debugging tips ==

Latest revision as of 13:26, 9 December 2009

connectors

The use of modular plugs like 8-position modular connector (8P8C or RJ45) or 6P4C (RJ11)? Is there any allowance for other than 8 position modular connectors? Some product (cheap dimmers) have 6 position connectors (RJ11).

Sender/receiver topologies

To avoid ground loops and improve reception performance, transmitters and/or receivers can be grounded/floating/non-isolated ??? http://www.usitt.org/standards/DMX512_FAQ.html#FAQ_15 There are different topologies, and not all will work together. There are no requirement for what topology to use in the DMX specification from 1990, so it was added to DMX512-A.

Transmitters should use "earth ground" as a reference for the positive/negative voltages that is put on the two data lines. If they don't, it must be clearly marked on the product and in the manual. Receivers should be ...?


Voltages

At http://www.dmx512-online.com/physl.html there is an example wit D1+ at +5V and D1- at -5V, and considering page 12 in this document from TI it is presumably a wrong interpretation.

This web page cites RS485 as having a upper limit of +12/-7 V with respect to ground. This probably refers to common mode loading voltages that receivers must work with. I.e. one of the data wires is allowed to reach +12 or -7 V but the opposite wire must not be at the other extreme, but only differ by 6 V maximum.



Debugging tips

Links to simple testers?

How can reverse polarity be detected?

  • The break at the very beginning of a packet must be low
  • If all transmitted data bytes have value zero, the DMX line should be low about 80 % of the time if there are no extra idle time between slots/frames or packets.