We've launched our new site at www.openlighting.org. This wiki will remain and be updated with more technical information.
Difference between revisions of "NonConformDMX"
From wiki.openlighting.org
m (Add Pro518 and Commet6) |
|||
(5 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
Feel free to add DMX equipment that does not conform to the ESTA DMX Spec. | Feel free to add DMX equipment that does not conform to the ESTA DMX Spec. | ||
+ | |||
+ | |||
+ | ---- | ||
'''Eurolite''' | '''Eurolite''' | ||
Eurolite ts-5: needs pause between DMX channels to work properly, standard says no pause is needed. When using with Enttec PRO and MagicQ, only movements (pan and tilt, two first channels of device) work, shutter and dimmer can't be controlled | Eurolite ts-5: needs pause between DMX channels to work properly, standard says no pause is needed. When using with Enttec PRO and MagicQ, only movements (pan and tilt, two first channels of device) work, shutter and dimmer can't be controlled | ||
− | ''' | + | |
+ | '''Comment:''' If you use 6 channels to control the ts-5, it works a little better, but it's still not perfect. channel 4 and 5 must be coupled(have the same value) and the new 6th channel does the dimmer. But there are still some uncontrolled movements of the gobo and colour wheel, except they have the same value(ch. 3,4&5); | ||
---- | ---- | ||
Line 10: | Line 14: | ||
Martin RoboScan Pro400: operates with a non-zero startcode. | Martin RoboScan Pro400: operates with a non-zero startcode. | ||
+ | |||
+ | Martin RoboScan Pro518: operates with a non-zero startcode. | ||
+ | |||
+ | Note: both have 3-pin XLR connectors, and include internal jumpers to reverse polarity for use with Martin Protocol. | ||
+ | |||
+ | ---- | ||
+ | |||
+ | '''Theatrelight''' | ||
+ | |||
+ | Commet 6 - single-phase 15A dimmer pack: operates with a non-zero startcode. | ||
+ | |||
+ | ---- |
Latest revision as of 16:17, 29 November 2012
Feel free to add DMX equipment that does not conform to the ESTA DMX Spec.
Eurolite Eurolite ts-5: needs pause between DMX channels to work properly, standard says no pause is needed. When using with Enttec PRO and MagicQ, only movements (pan and tilt, two first channels of device) work, shutter and dimmer can't be controlled
Comment: If you use 6 channels to control the ts-5, it works a little better, but it's still not perfect. channel 4 and 5 must be coupled(have the same value) and the new 6th channel does the dimmer. But there are still some uncontrolled movements of the gobo and colour wheel, except they have the same value(ch. 3,4&5);
Martin
Martin RoboScan Pro400: operates with a non-zero startcode.
Martin RoboScan Pro518: operates with a non-zero startcode.
Note: both have 3-pin XLR connectors, and include internal jumpers to reverse polarity for use with Martin Protocol.
Theatrelight
Commet 6 - single-phase 15A dimmer pack: operates with a non-zero startcode.